34 Bilder zum Thema "branche de faisceau gauche" bei ClipDealer

Medien sortieren nach     Gehe zu Seite:    
« Vorherige  1  Nächste »
In complete left bundle branch block, the conduction of the LBB can be completely interrupted or can still be conducted, but it is delayed by at least 45ms than the RBB.
In the spatial anatomy of the heart, the axis from the base of the heart to the apex of the heart is called the long axis, that is, the upper right side faces the lower left side.
Clockwise rotation electrocardiogram refers to the transition of the rS waveform of the chest lead to the left chest lead, with the transition lead exceeding the V4 lead.
Clockwise and counterclockwise rotation are common electrocardiographic phenomena, mainly used to describe the evolution of R-wave amplitude in chest leads.
A 2:1 left bundle branch block is considered when complete left bundle branch block alternates with normal QRS complexes and the PR interval is fixed.
Electric impulses can be conducted, but the conduction speed slows down, resulting in conduction delay and affecting the morphology of the P wave, PR interval, and QRS wave.
Due to the large mass of the left ventricle, the dominant excitation potentials of the left and right ventricles are oriented towards the left ventricle, i.e. towards the left, Inferior and posterior.
It is best to measure the QRS wave duration in a 12 lead synchronous electrocardiogram, as some of the QRS wave start and end points are located on the isoelectric line.
Electric impulses can be conducted, but the conduction speed slows down, resulting in conduction delay and affecting the morphology of the P wave, PR interval, and QRS wave.
The transverse vectorcardiogram generates a chest leads electrocardiogram, with the maximum ventricular excitation potential oriented towards the left posterior region.
On the conventional 12-lead ECG, under normal circumstances, there are some inherent patterns of QRS waves in different leads, which are not exactly the same.
Under normal circumstances, in the chest lead electrocardiogram, the amplitude of the R wave gradually increases from lead V1 to lead V6.
The terminal excitation of the ventricle forms the final part of the S wave in lead V1, gradually returning to the isoelectric line, and forms a small S wave in lead V5.
In humans, Purkinje fibers are not distributed throughout the entire ventricular wall, but rather in the superficial myocardium beneath the endocardium and do not reach the epicardium.
QRS wave is a ECG wave generated by ventricular excitation, typically in a three-phase waveform, named qRs wave. The QRS waveform of each lead is different.
Abnormal ECG refers to changes in depolarization waves and or repolarization waves, most of which are pathologic and few are physiological.
QRS wave is a ECG wave generated by ventricular excitation, typically in a three-phase waveform, named qRs wave. The QRS waveform of each lead is different.
The initial excitation of the ventricle forms a small r wave in lead V1 and a small q wave in lead V6.
When a  2:1 bundle branch block occurs, the refractory period of the bundle branch is longer than one basal cardiac cycle but shorter than two basal cardiac cycles.
Male, 13 years old, clinically diagnosed with secundum atrial septal defect. Note that the QRS wave in lead V1 of the electrocardiogram has a qR shape, indicating right ventricular hypertrophy.
Sometimes, there may be slight non-specific changes and normal variations in the electrocardiogram, which are often due to physiological reasons and have no clinical therapeutic significance.
Abnormal ECG refers to changes in depolarization waves and or repolarization waves, most of which are pathologic and few are physiological.
During normal ventricular excitation, the earliest epicardial breakthrough point is located in the paraventricular septal area, and the RV outflow tract and the base of the LV are finally excited.
Narrow QRS wave and wide QRS wave
The high lateral  lead group includes leads I and aVL, used to explore the myocardium of the high lateralwall of the left ventricle.
The conduction system of the heart is supplied by the branches of the coronary artery. Once the blood vessels are blocked, it can cause conduction disorder. This picture is suitable for dark background. This picture is suitable for light background.
When there are more than 3 components in the QRS wave of lead V1, do not diagnose it as right bundle branch block, as this is a manifestation of fragmented QRS wave.
The conduction in ventricle is mainly divided into right bundle branch and left bundle branch. The left bundle branch includes left anterior fascicle and left posterior fascicle.
Electric impulses can be conducted, but the conduction speed slows down, resulting in conduction delay and affecting the morphology of the P wave, PR interval, and QRS wave.
On a conventional 12 lead electrocardiogram, the QRS wave of complete right bundle branch block in lead V1 is usually an rSR three-phase waveform.
The His bundle and the proximal bundle branches are mainly supplied by the 1st septal branch of the left anterior descending branch and the atrioventricular node artery of the right coronary artery.
In a wide QRS rhythm, the nature of the P wave can be observed in leads with lower QRS wave amplitudes. In this case, retrograde P waves can be seen in leads aVR and aVL.
In a wide QRS rhythm, the nature of the P wave can be observed in leads with lower QRS wave amplitudes. In this case, retrograde P waves can be seen in leads aVR and aVL.
At present, the definition of narrow QRS complex is QRS durationgreater than or equal to 120ms, and wide QRS complex is defined as QRS duration beyond 120ms.